Top HMI factory

Top hmi touch screen panel manufacturer: Specifically, the two-way communication between the HCI user and the machine containing the computer, in a certain symbol and actions to achieve, such as hitting keys, moving the mouse, displaying symbols/graphics on the screen, etc. This process includes several sub-processes: identifying the interactive object – understanding the interactive object – grasping the object situation – information adaptation and feedback, etc.; and the human-machine interface is the communication media or means between the user and the machine system containing the computer, which is the software and hardware supporting the two-way information interaction between human and machine. Here the interface is defined as the media or means of communication, and its physical embodiment is the relevant supporting software and hardware, such as a graphic display terminal with a mouse, etc. Read additional information at hmi panel.

Reasonable Structural Type: There are two structural types: main module and extended module. The average price of each I/O point of the integral PLC is cheaper than that of the module type, and the volume is relatively small, which is generally used in the small control system with a fixed system process; The function expansion of module plc is flexible and convenient, and there is a large choice in the number of I/O points, the ratio of input points to output points, the type of I/O modules…etc, and the maintenance is convenient, generally in more complex control systems.

Frequency principle: That is, according to the frequency of dialogue interaction of the management object design the human-machine interface hierarchical order and dialogue window display position of the list, etc., to improve the frequency of monitoring and access to dialogue. Importance principle: That is, in accordance with the importance of management objects in the control system and the global level, the design of the human-machine interface of the main and secondary menus and the location and prominence of the dialogue window, which helps managers to grasp the importance of the control system, the implementation of good control of the sequence of decisions to achieve optimal scheduling and management.

Consider the typical problems in interface design: To design any interface, we must generally consider four aspects: system response time, user help mechanism, error message handling and command mode. System response time is too long is the most complained about in the interactive system, in addition to the absolute length of the response time, the user is concerned about the difference in response time of different commands, if too much disparity in the user will be difficult to accept; user help mechanism should be integrated, to avoid the superimposed system leads to the user to help a guide and have to browse a lot of irrelevant information; error and warning information must be selected user understandable The error and warning messages must be user-friendly, accurate terminology, and should also provide some suggestions for error recovery as much as possible. In addition, the display of error information, if supplemented by auditory (ringing), visual (special color) stimulation, it is more effective; command mode is best to menu and keyboard commands coexist for the user to choose.

The Fourth Step: Communication Mode Preference is given to the HMI Panel itself with lower computer drive touch screen. Firstly, this is will be more convenient and simple in the definition of the subsequent project address and conversion, becuase if you choose Modbus compatible devices, it is necessary to convert the HMI touch screen monitoring address according to the rules of the definition of different lower computer(PLC) manufacturer, which not only greatly increase the workload of engineers and also easy to covert the wrong. Secondly, needing to draw up in advance, a communication program for the entire project. Do it need the ethernet to communicate with the upper computer, or need two rs485 to be maste or slave station communication, or through one rs485 and one rs232 communication to achieve.

Supporting customized special technical parameters, special application scenarios or special process, special function realization, special performance, special application including shape, color etc. With NO MOQ before mass production. And will not accept to quantity production before customer 100% confirmation its stable quality to run in the device or equipment. Becuase quality is the soul of an enterprise. MochuanDrives customized pmsm motor mainly focuses on high-tech , high-end development, design, production, sales. Find even more details at https://www.mochuan-drives.com/.

How To Solve Communication Failure Between HMI Operator Interface And PLC? When communication fails, some customers guess that it may be a problem with the touch screen all-in-one machine or the interface. Online simulation is to bypass the touch screen, use the PLC to connect directly to the computer, use our configuration software, connect the PLC’s own communication cable to the computer, conduct online simulation and see if the project can communicate.

This type touchscreen panel support 7inch, 9.7inch, 17inch, 22inch and 32inch, is enough to select suitable model for the project from application and cost. There are two operating temperature -10°C to 60°C and -20°C to 70°C. And all the size and model is to support ethernet, 2pcs rs485 or 2pcs rs232 is in optional. Adpoting industrial grade high quality components, high protection level design, comprehensive three-proof coating, no matter the wet underground mine, high temperature gobi or corrosive gas, oil mist or dust factory environment, can easily cope with, easy to handle.

There are lots of temperature control in industry automation. It can select temperature module match the main module plc temperature controller, it also use independent temperature controller to control, both of them are to achieve temperature control. If wanna more flexibility in temperature control, maybe indenpendent temperature module is the first choice. Becuase it can operate without main module plc controller. Mochuan independent plc temperature module integrates an excellent self-tuning algorithm, and user can auto-tune with one button according to needs to accurately obtain PID parameters. Through rs485 communication port, communicate with upper computers of various brands, types of plc, touch screen hmi, configuration software and other upper computers to complete morecomplex logic temperature control.

MochuanDrives supports industrial hmi touch panel from 4.3inch to 32inch, and supports multiple serial ports with different communication parameters to meet the needs of different projects. Provide free software and online technical one-on-one worry-free after-sales technical support. Through the setting of early warning programming, can monitor in advance whether there is a failure of the equipment in the electrical room, can effectively prevent the loss of sudden damage to equipment.

Comments are closed.

Categories